Where is the moisture?
Before anything else, find out which surface the water is on. A double- or triple-pane window has four or six glass surfaces, and condensation on each one means something different.
- On the room side of the glass: this is usually indoor humidity meeting cold glass, not a broken window. Showers, cooking, drying laundry and humidifiers all add moisture, and the window is often the coldest surface in the room. Running vented bath and kitchen fans and lowering a humidifier setting usually helps.
- On the outside surface: common on cool, still mornings, and it burns off as the sun warms the glass. It is a sign the glass is keeping heat in, not a defect.
- Between the panes: moisture that won’t wipe off from either side, a milky film, or streaks and spots on the inner faces of the glass mean the sealed unit has failed. That is what foggy window repair fixes.
Why sealed glass units fail
An insulating glass unit (IGU) is two or more panes held apart by a spacer around the edge. The spacer contains a desiccant that soaks up the small amount of moisture sealed inside, and a perimeter sealant keeps outside air out. Many units also have an argon or other gas fill and a Low-E coating on one of the inner surfaces.
Every day the air between the panes heats and cools, pushing and pulling on the edge seal. Over years, that cycling, along with water standing against the bottom edge and strong sun on exposed walls, wears the seal. Once moist air gets in and the desiccant is saturated, fog forms. Early on it may appear only on certain days and clear as the glass warms; the glass industry treats a unit as failed once the obstruction is permanent.
What the fix looks like
A sealed unit cannot be wiped clean from the inside, so the usual repair is a new IGU in the existing sash or frame:
- Confirm the failure and check the sash and frame around it, since a rotted or warped sash is a reason to replace more than the glass.
- Measure the unit, including its overall thickness, so the new one fits the existing glazing pocket. Sealed units are generally made to order to those dimensions.
- Remove the glazing stops or beads, take out the old unit and clean the pocket.
- Set the new unit on setting blocks so its bottom edge stays out of standing water, then reinstall the stops and seal it.
On some windows the sealed unit is glued in place as part of the sash, and the practical repair is a new sash rather than loose glass. If the frame itself is failing, window replacement is the better route.
What about “defogging”?
Some services drill small holes in the glass, dry the space between the panes and plug the holes. That can clear the view, but whether it treats more than the symptom is debated: the edge seal that let moisture in is still broken, and any insulating gas that escaped is not put back. If efficiency matters, a new sealed unit is the more dependable fix.
Does it matter if I leave it?
A foggy unit still keeps weather out, so it is rarely urgent. But a failed unit may have lost some of its gas fill and insulate less well. The view keeps getting worse, and a white haze or mineral spotting can build up on the inner faces of the glass. If several windows of the same age are starting to fog, it is worth asking whether new glass or energy-efficient replacement windows make more sense for the whole set.
Check it yourself first
- Wipe both faces of the glass with a dry cloth. If the haze stays, it is between the panes.
- Look at it at different times of day. Fog that comes and goes is often an early seal failure.
- Find any label or printing on the metal or foam spacer between the panes, and note it.
Call or text (614) 333-6302 or book online to have the glass measured.