Every sleeping room, including a bedroom in a basement, needs an emergency escape and rescue opening: a window or door large enough to climb out of and for a firefighter to get in. The Residential Code of Ohio sets the minimum size and sill height, and below‑grade windows need a well large enough to climb out of. We size egress windows to the code and plan the opening and well with you.

  • Based in Columbus at 1221 Stimmel Rd
  • Homes within about 55 miles of Columbus
  • We look at the window first; you get the price before work starts
  • Frame
  • Sash
3D model · drag or use the arrows to rotate
Design your window in 3D

Signs you need egress windows

You might notice…

Safety first. Cutting or enlarging an opening in a foundation or bearing wall is structural work that usually needs a building permit. Never cut into a foundation without checking for buried utilities outside.

Built before 1978? Lead paint and window work.

  • A basement being finished with a bedroom or a room that may be used as one
  • A bedroom window that is too small or too high to climb out of
  • An old, small basement window in a room that is now used for sleeping
  • A home sale or inspection that flagged a bedroom without an escape window

What’s included

Looked at, explained, then fixed.

  • Measuring the room, the existing opening and the grade outside
  • Window style and size chosen to meet the clear-opening rules
  • Planning for enlarging the opening and the well, where needed
  • The window installed, insulated, sealed and trimmed
  • A well of the required size, with a ladder or steps where it’s deep
  • A check that the window opens fully and easily from inside
  1. 01
    Call or book

    Tell us which room and whether there is a window there now.

  2. 02
    Measure

    We measure the room, the wall and the ground outside, and check what the code requires.

  3. 03
    You see the price

    You get a written price for the window, opening and well before work starts.

  4. 04
    Install

    We install the window and well and check that it opens fully for an easy escape.

Pricing

How pricing works

Every window is different: its size, its glass, what has failed and how it is built. So we look at it before we quote, and you get the price before any work starts.

How window pricing works

More on egress windows

Why escape windows exist

If a fire blocks the stairs, a bedroom window may be the only way out, and the only way in for a firefighter. That is the reason the Residential Code of Ohio requires an emergency escape and rescue opening in sleeping rooms, and why the size of that opening is set out in numbers rather than left to taste.

When Ohio’s code requires one

  • Every sleeping room needs at least one operable emergency escape and rescue opening.
  • A new bedroom in an existing basement needs one. Finishing a basement into living space that has no sleeping room does not by itself trigger the requirement.
  • A new sleeping room in an addition needs one.

The code has a limited exception for basement sleeping rooms in homes with an automatic sprinkler system and a second way out of the basement. Ohio updates its residential code from time to time, and local building departments apply it, so confirm the current rules with your city or county building department before you plan a basement bedroom.

The dimensions

These are the minimums in the Residential Code of Ohio, measured on the clear opening you could climb through with the window fully open, not on the window’s frame size:

  • Net clear opening area: at least 5.7 square feet; at least 5 square feet for a window at grade floor or below grade.
  • Net clear opening height: at least 24 inches.
  • Net clear opening width: at least 20 inches.
  • Sill height: no more than 44 inches above the floor.
  • Operation: it must open from inside without keys, tools or special knowledge. Any window opening control device on it must comply with ASTM F2090 and release for escape.

Meeting the height and width minimums at the same time does not meet the area minimum, so all three have to be checked together.

Window wells

When the sill is below the ground outside, the window needs a well. The code calls for a well with at least 9 square feet of floor area and at least 36 inches of projection and width, big enough that the window can open fully. If the well is deeper than 44 inches, it needs a permanently attached ladder or steps usable with the window open. A window under a deck or porch needs a path at least 36 inches high out to the yard. The well should also drain, so water does not pond against the glass.

Which window style works

  • Casements open fully, so they meet the clear-opening numbers at the smallest overall size. The sash swings out, so the well has to be big enough for it.
  • Sliders open half their width, so the frame has to be wide enough that the open half clears 20 inches and the area minimum.
  • Double-hungs open half their height, so they need a tall frame to clear 24 inches of opening height.

Replacing an existing bedroom window

Ohio’s code gives replacement windows a narrow exemption from the size and sill-height rules, but only when the new window is the manufacturer’s largest standard size that fits the existing frame or rough opening, it is the same operating style as the old one or has an equal or greater opening, and the work is not part of a change of occupancy. In practice, if a bedroom window is being replaced anyway, it is a good moment to check whether a different style would give a code-sized opening in the same space.

Cutting a new basement opening

Creating an egress window where there was a small basement window, or none at all, means cutting the foundation wall, setting a header or lintel to carry the load above, installing the well and drainage, and flashing and sealing the new window. Before the job is scheduled, check with your city or county building department and ask the contractor who obtains any permit and arranges inspection. Ask too about buried utilities near the dig, and where the well’s drainage will go.

Questions to ask any contractor

  1. What is the net clear opening area, height and width of the exact window quoted?
  2. What will the sill height be from the finished floor?
  3. How large and how deep is the well, and does it need a ladder?
  4. How does the well drain?
  5. Who handles the permit and the inspection?

Plan it before the drywall goes up

If you are finishing a basement, the egress opening is easiest to plan before the walls are framed. A technician looks at the room and the outside wall before anything is quoted, and you see the price before work starts. Call or text (614) 333-6302, or book online.

Call or text · Columbus, OH

Planning new windows?

(614) 333-6302
  • We measure before we quote
  • Columbus-based · 55-mile service area

FAQ

Egress windows questions

Call or text (614) 333-6302 if you don’t see your question here.

What size does an egress window have to be in Ohio?

Under the Residential Code of Ohio, an emergency escape opening needs a net clear opening of at least 5.7 square feet (5 square feet for grade-floor and below-grade openings), at least 24 inches of clear height and at least 20 inches of clear width. The window itself has to open that wide, not just the frame.

How high can the sill of an egress window be?

No more than 44 inches above the floor, measured to the bottom of the clear opening.

Does a basement egress window need a window well?

When the window is below ground level, yes. The well must have at least 9 square feet of area and be at least 36 inches wide and 36 inches out from the window. A well deeper than 44 inches needs a permanently fixed ladder or steps.

Does every bedroom need an egress window?

Every sleeping room needs at least one emergency escape and rescue opening, which can be a window or an exterior door. A basement with a bedroom needs one in that bedroom.

What window styles work best for egress?

Casements, because the whole sash opens, reach the clear-opening size with the smallest window. Sliders and double-hungs work too but need a larger unit, since only part of the window opens.

Do I need a permit for an egress window?

Usually, when a new opening is cut or an existing one is enlarged, since that changes the structure. Requirements depend on the city or county, so check with the local building department first.

Does every basement need an egress window?

Under the Residential Code of Ohio the requirement is tied to sleeping rooms. A basement with a new bedroom needs an escape opening in that room; alterations to an existing basement that add no sleeping room do not by themselves require one. Confirm with your local building department, since it applies the code.

Can I put bars or a lock on an egress window?

Anything on an escape window has to let it open from inside without keys, tools or special knowledge. Window opening control devices are allowed only when they meet ASTM F2090 and release for escape, and they cannot reduce the required clear opening.

Is the window size the same as the clear opening?

No. The clear opening is the space you can actually climb through with the window fully open, after the frame, the fixed sash and any hardware. A window can be larger than 5.7 square feet overall and still have a clear opening below it.

Where we work

Egress windows across Central Ohio

Egress windows in Columbus and the communities within about 55 miles of our shop.

All 52 communities we serve

Map of Columbus and 51 nearby communities A1 Windows serves within about 55 miles of its shop.

Rivers © OpenStreetMap contributors

Homeowner guides

Guides for egress windows in Columbus

All guides

Egress windowsNov 21, 2026 · 5 min read

Basement Egress Windows in Ohio: What the Code Requires

If you’re turning part of a basement into a bedroom, the window is not a finishing detail. Under the Residential Code of Ohio, every sleeping room needs a way out that doesn’t depend on the stairs, and the rules for that opening are specific.

Window replacementNov 21, 2026 · 4 min read

Insert vs. Full-Frame Window Replacement: How to Choose

Every replacement window goes in one of two ways. An insert, sometimes called a pocket replacement, slides a new window unit into the existing frame after the old sashes come out, while a full-frame replacement removes everything down to the rough opening.

Window replacementNov 21, 2026 · 5 min read

Pre-1978 Homes and Window Work: The EPA Lead-Safe Rules

If your home was built before 1978, paying someone to replace or repair its windows is regulated work. Windows are one of the places lead-based paint matters most, because sashes rub against painted frames every time they open and close.

Step 1 of 4

Book a window visit

What’s going on with your windows?

Pick the closest match to continue. You can add details on the next step.